<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-10 00-41-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 58 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.0 kHz -12 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 70 kHz 10077 30,8127
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,4 dBr 7,77 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 0:41, 10.02.2025
RT
"MATT SIMONS - We Can Do Better "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (58 dBuV) Max at: 70 kHz MIN: 11 kHz % above 75 kHz: 30,8127 Acquired: 2025/02/10 0:40:41 Total samples: 10077 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 8,3 dBr MIN: 6,4 dBr AVE: 7,77 dBr % above 10,0 dBr: 0,0 Last value: 7,2 dBr (2025/02/10 0:40:41) Station: 96.90 MHz, signal: 4/5 (59 dBuV) 00:34 00:35 00:36 00:37 00:38 00:39 00:40 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality